BNQWG - 1012, FAULT FINDER PENETRANT GROUP IA
- MSDS: BNQWG
- Manufacturer: CROWN INDUSTRIAL PRODUCTS CO INC
- Product Name: 1012, FAULT FINDER PENETRANT GROUP IA
- National Stock Number: 6850-00N031044
Product Identification
Product ID:1012, FAULT FINDER PENETRANT GROUP IA
MSDS Date:04/14/1986
FSC:6850
NIIN:00N031044
MSDS Number: BNQWG
Responsible Party
HEBRON, IL 60034
US
Emergency Phone: 815-648-2424
Info Phone: 815-648-2424
Preparer: ROBERT E. BAYTON
Cage: 92381
Contractor
Telephone: 815-648-2424
Cage: 92381
Ingredients
POLY(OXY(METHYL-1,2-ETHANEDIYL)),
CAS: 9003-13-8
RTECS: TR4680000
Fraction By Weight: 11-30%
RESIDUES (PETROLEUM), CATALYTIC REFORMER
CAS: 64741-67-9
RTECS: VG7067000
Fraction By Weight: 31-50%
ACGIH TLV: 200 PPM (MFR)
KEROSENE;(HYDROCARBON FRACTION)
CAS: 8008-20-6
RTECS: OA5500000
Fraction By Weight: 11-30%
OSHA PEL 100 PPM
ACGIH TLV: 200 PPM (MFR)
2-PYRROLIDINONE, 1-METHYL;(N-METHYLPYROLIDINONE)
CAS: 872-50-4
RTECS: UY5790000
Fraction By Weight: 1-10%
ACGIH TLV: 200 PPM (MFR)
HYDROCARBON PROPELLANT;(LIQUIFIED PETROLEUM GAS, SWEETENED)
CAS: 68476-86-8
Fraction By Weight: 11-30%
ACGIH TLV: 1000 PPM (MFR)
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL:CAN CAUSE HEADACHE, DIZZINESS
AND NAUSEA. INGEST:NONE ESTABLISHED. EYE:CAN CAUSE SEVERE
IRRITATION. SKIN:CAN CAUSE DRYING OF THE SKIN & DERMATITIS.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYE:FLUSH WITH WATER FOR AT LEAST 15 MINUTES OR UNTIL
IRRITATION SUBSIDES. SKIN:REMOVE ALL CONTAMINATED CLOTHING. WASH
SKIN WITH SOAP & WATER. INHAL:MOVE FROM EXPOSURE IMMEDIATELY. IF
BREATHING IRREGU LAR OR STOPPED, BEGIN ARTIFICIAL RESPIRATION AND
GIVE O2. INGEST: DRINK WATER AND INDUCE VOMITNG.
Fire Fighting
Flash Point Method:TCC
Flash Point:<20F,<-7C
Lower Limits:1.8%
Upper Limits:9.5%
Extinguishing Media:CARBON DIOXIDE, FOAM, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA &FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:TREAT AS CYLINDERS OF COMPRESSED GAS.
Accidental Release
Spill Release Procedures:VENTILATE AREA. REMOVE ALL SOURCES OF
IGNITION. CLEAN UP WITH INERT MATERIALS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:AEROSOL CONTAINER:DO NOT STORE IN
DIRECT SUNLIGHT, NEAR OPEN FLAMES OR >120F.
Other Precautions:USE ONLY AS DIRECTED. INTENTIONAL MISUSE BY
DELIBERATELY CONCENTRATING VAPORS & INHALING CONTENTS CAN BE
HARMFUL/FATAL.
Exposure Controls
Respiratory Protection:RESPIRATORY PROGRAM SHOULD BE IN ACCORDANCE WITH
29 CFR 1910.134. NIOSH/MSHA APPROVED RESIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:LOCAL EXHAUST IS ADEQUATE.
Protective Gloves:POLYETHYLENE OR NEOPRENE GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:PROTECTIVE CLOTHING AND EQUIPMENT:SEE 20 CFR
1910.132 AND 133.
Work Hygienic Practices:WASH SKIN WITH SOAP & WATER.
Supplemental Safety and Health
VAP PRESS:AEROSOL @ 70F:40-50 PSIG.
Chemical Properties
HCC:V3
Vapor Pres:SUPP DATA
Vapor Density:>1
Spec Gravity:<1
Evaporation Rate & Reference:<1 (ETHER=1)
Solubility in Water:NEG
Appearance and Odor:RED WITH AROMATIC ODOR
Percent Volatiles by Volume:30
Stability
Stability Indicator/Materials to Avoid:YES
AVOID CONTAMINATION WITH CAUSTIC SODA, CAUSTIC POTASH OR OXIDIZING
MATERIALS.
Stability Condition to Avoid:OPEN FLAMES, SPARKS, ELECTRICAL ARCS.
Hazardous Decomposition Products:THERMAL DECOMPOSITION MAY YIELD CO,
CO2 AND OTHER TOXIC MATERIALS IN SMALL QUANTITIES.
Disposal
Waste Disposal Methods:DISPOSE IN ACCORDANCE WITH ALL LOCAL, STATE, AND
FEDERAL REGULATIONS. AEROSOL CONTAINERS:DO NOT PUNCTURE OR
INCINERATE. EMPTY CONTAINERS MAY BE DISPOSED OF THROUGH NORMAL
CHANNELS. FULL/PARTIALLY FILL ED CNTNRS ARE CONSIDERED HAZARDOUS
WASTE.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.